[. . . ] HP Insight Management Agents User Guide Part number: 308447-004A Fourth edition: March 2006 Legal notices © Copyright 2002--2006 Hewlett-Packard Development Company, L. P. Consistent with FAR 12. 211 and 12. 212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U. S. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. [. . . ] If the failure count is not zero and the drive has failed, replace the drive. Storage Agent information 86 If the counter is not zero and the drive has not failed, there might be an intermittent problem that requires drive replacement. If you observe that the count is increasing over time, replace the drive. · Aborted Commands--The Aborted Commands counter records the number of times that a physical SCSI drive returned an Aborted Command status when a SCSI command was attempted. This error count indicates unsuccessful termination of the SCSI command. When the physical drive is failed because of aborted commands that could not be retried successfully, Aborted Commands errors occur. If the number of errors is not zero and the drive has failed, replace the drive. If the counter is not zero and the drive has not failed, there might be an intermittent problem that requires drive replacement. If you observe that the count is increasing over time, replace the drive. · Reallocation Aborts--When the physical drive is failed due to an error that occurred when the controller was trying to reallocate a bad sector, a Reallocation Abort error occurs. Because of the nature of magnetic disks, certain sectors on a drive might have media defects. The reallocation area part of the drive is set aside to compensate for these defects. The array controller writes information addressed from unusable sectors to available sectors in the reallocation area. If the number of Reallocation Abort errors is not zero and the drive has failed, replace the drive. If the counter is not zero and the drive has not failed, there might be an intermittent problem that requires drive replacement. If you observe that the count is increasing over time, replace the drive. · Media Failures--When this physical drive fails because of unrecoverable media errors, a Media Failure occurs. If the number of media failure errors is not zero and the drive has failed, replace the drive. If the counter is not zero and the drive has not failed, there might be an intermittent problem that requires drive replacement. If you observe that the count is increasing over time, replace the drive. · Format Errors--When a format operation fails because the controller was unable to remap a bad sector, a Format Error occurs. If the number of Format Errors is not zero and the drive has failed, replace the drive. If the counter is not zero and the drive has not failed, there might be an intermittent problem that requires drive replacement. [. . . ] HP Utilities have the capability to set up or modify your system and include various diagnostic programs. A feature of HP Systems Insight Manager that allows you to monitor HP PCs being used as clients. Refers to the capacity to deliver information through existing network hardware. Synonymous with "on the network. " Multiple physical drives connected in a HP Drive Array to the same controller and combined to create logical drives. [. . . ]